View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0002823 | SymmetricDS | Bug | public | 2016-09-22 14:21 | 2016-09-30 01:01 |
Reporter | elong | Assigned To | elong | ||
Priority | normal | ||||
Status | closed | Resolution | fixed | ||
Product Version | 3.7.0 | ||||
Target Version | 3.8.5 | Fixed in Version | 3.8.5 | ||
Summary | 0002823: Value too large for router_id in sym_data_event error | ||||
Description | For triggers on the SYM tables, the router_id is generated by concatenating the trigger_id with source_node_group_id and target_node_group_id, and then it is saved in sym_data_event during routing. If the user has specified large names in the configuration, the router_id will exceed the 50 characters defined for it on sym_data_event. Caused by: java.sql.BatchUpdateException: value too large for column "SYM_DATA_EVENT"."ROUTER_ID" (actual: 51, maximum: 50) | ||||
Tags | No tags attached. | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2016-09-22 14:21 | elong | New Issue | |
2016-09-22 14:21 | elong | Status | new => assigned |
2016-09-22 14:21 | elong | Assigned To | => elong |
2016-09-22 16:00 | admin | Changeset attached | => SymmetricDS 3.8 1aa51b08 |
2016-09-23 12:33 | elong | Resolution | open => fixed |
2016-09-23 12:33 | elong | Fixed in Version | => 3.8.5 |
2016-09-23 12:33 | elong | Target Version | => 3.8.5 |
2016-09-23 12:33 | elong | Status | assigned => resolved |
2016-09-30 01:01 | admin | Status | resolved => closed |