View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0006664 | SymmetricDS Pro | Bug | public | 2024-12-03 19:38 | 2024-12-05 14:19 |
Reporter | emiller | Assigned To | emiller | ||
Priority | normal | ||||
Status | closed | Resolution | fixed | ||
Product Version | 3.15.4 | ||||
Target Version | 3.15.11 | Fixed in Version | 3.15.11 | ||
Summary | 0006664: DB2 AS400 log miner can lose precision when reading numeric values | ||||
Description | When reading numeric values, the DB2 AS400 log miner can lose precision. Values with 8 or more digits can get converted to exponential notation. This can result in them losing significant figures or being rounded. For example, a value of 20241203 gets converted to 2.0241204E7 or 20241204. | ||||
Tags | dialect: as/400, log miner | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2024-12-03 19:38 | emiller | New Issue | |
2024-12-03 19:38 | emiller | Status | new => assigned |
2024-12-03 19:38 | emiller | Assigned To | => emiller |
2024-12-03 19:38 | emiller | Tag Attached: dialect: as/400 | |
2024-12-03 19:38 | emiller | Tag Attached: log miner | |
2024-12-03 19:46 | emiller | Status | assigned => resolved |
2024-12-03 19:46 | emiller | Resolution | open => fixed |
2024-12-03 19:46 | emiller | Fixed in Version | => 3.15.11 |
2024-12-05 14:19 | pbelov | Note Added: 0002546 | |
2024-12-05 14:19 | pbelov | Status | resolved => closed |