View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0002652 | SymmetricDS Pro | Bug | public | 2016-06-29 12:15 | 2016-08-16 19:36 |
Reporter | josh-a-hicks | Assigned To | josh-a-hicks | ||
Priority | normal | ||||
Status | closed | Resolution | fixed | ||
Product Version | 3.7.0 | ||||
Target Version | 3.8.1 | Fixed in Version | 3.8.1 | ||
Summary | 0002652: Using the standard 2 tier profile does not cleanup properly if there were previous entries in sym tables. | ||||
Description | If a previous installation of SymmetricDS left data in the group, group_link, router, node, or node_security tables selecting the standard two tier profile in the node setup wizard would fail with foreign key errors since the profile script did not clean up in the proper order. | ||||
Tags | No tags attached. | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2016-06-29 12:15 | josh-a-hicks | New Issue | |
2016-06-29 12:15 | josh-a-hicks | Status | new => assigned |
2016-06-29 12:15 | josh-a-hicks | Assigned To | => josh-a-hicks |
2016-06-29 12:35 | josh-a-hicks | Status | assigned => resolved |
2016-06-29 12:35 | josh-a-hicks | Fixed in Version | => 3.8.0 |
2016-06-29 12:35 | josh-a-hicks | Resolution | open => fixed |
2016-08-10 15:04 | chenson | Fixed in Version | 3.8.0 => 3.8.1 |
2016-08-12 15:01 | elong | Target Version | 3.8.0 => 3.8.1 |
2016-08-16 19:36 | admin | Status | resolved => closed |