View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0003745 | SymmetricDS Pro | Improvement | public | 2018-10-05 18:00 | 2018-10-31 20:31 |
Reporter | elong | Assigned To | elong | ||
Priority | normal | ||||
Status | closed | Resolution | fixed | ||
Product Version | 3.8.0 | ||||
Target Version | 3.9.15 | Fixed in Version | 3.9.15 | ||
Summary | 0003745: Load wizard backwards compatible with 3.7 and below for receiving an initial load | ||||
Description | The load wizard starting in 3.8 uses the sym_table_reload_request to send and receive loads. In that version, the table definition changed and became incompatible with version 3.7 and earlier. Make the load wizard detect the software version (sym_node.symmetric_version) and use the older method for receiving a load, which flips the rev_initial_load_enabled flag. For an older version, the user cannot select specific tables or options. It should also try to display information about legacy parameters on the summary screen to let the use know if creates or deletes will be performed. | ||||
Tags | No tags attached. | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2018-10-05 18:00 | elong | New Issue | |
2018-10-05 18:00 | elong | Status | new => assigned |
2018-10-05 18:00 | elong | Assigned To | => elong |
2018-10-05 18:04 | elong | Status | assigned => resolved |
2018-10-05 18:04 | elong | Resolution | open => fixed |
2018-10-05 18:04 | elong | Fixed in Version | => 3.9.15 |
2018-10-31 20:31 | mmichalek | Status | resolved => closed |