Summary0003745: Load wizard backwards compatible with 3.7 and below for receiving an initial load
DescriptionThe load wizard starting in 3.8 uses the sym_table_reload_request to send and receive loads. In that version, the table definition changed and became incompatible with version 3.7 and earlier. Make the load wizard detect the software version (sym_node.symmetric_version) and use the older method for receiving a load, which flips the rev_initial_load_enabled flag. For an older version, the user cannot select specific tables or options. It should also try to display information about legacy parameters on the summary screen to let the use know if creates or deletes will be performed.
TagsNo tags attached.

Activities

There are no notes attached to this issue.

Issue History

Date Modified Username Field Change
2018-10-05 18:00 elong New Issue
2018-10-05 18:00 elong Status new => assigned
2018-10-05 18:00 elong Assigned To => elong
2018-10-05 18:04 elong Status assigned => resolved
2018-10-05 18:04 elong Resolution open => fixed
2018-10-05 18:04 elong Fixed in Version => 3.9.15
2018-10-31 20:31 mmichalek Status resolved => closed