View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0005127 | SymmetricDS Pro | Bug | public | 2021-11-19 16:10 | 2021-12-11 17:09 |
Reporter | emiller | Assigned To | emiller | ||
Priority | normal | ||||
Status | closed | Resolution | fixed | ||
Product Version | 3.13.0 | ||||
Target Version | 3.13.1 | Fixed in Version | 3.13.1 | ||
Summary | 0005127: Editing staging files via the Manage Staging Area screen doesn't work if compression or encryption is enabled | ||||
Description | When editing a staging file via the Manage Staging Area screen, the text in file doesn't show up correctly if either stream.to.file.compression.enabled or stream.to.file.encrypt.enabled is set to true. It should be possible to edit staging files even if these parameters are enabled. | ||||
Tags | No tags attached. | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2021-11-19 16:10 | emiller | New Issue | |
2021-11-19 16:10 | emiller | Status | new => assigned |
2021-11-19 16:10 | emiller | Assigned To | => emiller |
2021-11-22 16:21 | emiller | Status | assigned => resolved |
2021-11-22 16:21 | emiller | Resolution | open => fixed |
2021-11-22 16:21 | emiller | Fixed in Version | => 3.13.1 |
2021-12-11 17:09 | admin | Status | resolved => closed |