View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0005549 | SymmetricDS Pro | Bug | public | 2022-10-21 19:36 | 2022-11-30 21:22 |
Reporter | emiller | Assigned To | emiller | ||
Priority | normal | ||||
Status | closed | Resolution | fixed | ||
Product Version | 3.13.0 | ||||
Target Version | 3.13.9 | Fixed in Version | 3.13.9 | ||
Summary | 0005549: Leaving table selection screen of Load Data Wizard while editing a where clause causes unexpected behavior | ||||
Description | Leaving the table selection screen of the Load Data Wizard while the grid editor is still open causes unexpected behavior if the user returns to the screen. Not only will the screen be blank, but if the user goes back to the first screen of the wizard, the "Next" button will become a disabled "Finish" button, which prevents the user from continuing through the wizard. | ||||
Tags | No tags attached. | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2022-10-21 19:36 | emiller | New Issue | |
2022-10-21 19:36 | emiller | Status | new => assigned |
2022-10-21 19:36 | emiller | Assigned To | => emiller |
2022-10-21 19:37 | emiller | Issue cloned: 0005550 | |
2022-10-21 19:37 | emiller | Relationship added | related to 0005550 |
2022-10-21 20:13 | emiller | Summary | Leaving where clause screen of Load Data Wizard while editing a where clause causes unexpected behavior => Leaving table selection screen of Load Data Wizard while editing a where clause causes unexpected behavior |
2022-10-21 20:13 | emiller | Description Updated | View Revisions |
2022-10-21 20:13 | emiller | Status | assigned => resolved |
2022-10-21 20:13 | emiller | Resolution | open => fixed |
2022-10-21 20:13 | emiller | Fixed in Version | => 3.13.9 |
2022-11-30 21:22 | admin | Status | resolved => closed |