Summary | 0005977: Database performance test broken on SQL-Server and others | ||||
Description | The database performance test on the Manage -> Nodes screen under Test -> Database does not work on SQL-Server, Sybase ASE, SQL Anywhere, Informix, and SQLite because of bad SQL syntax. It tries to create a table with a data type of "timestamp" on SQL-Server which is actually a "rowversion", not a "datetime". It uses "current_timestamp" which is not available on the other database platforms. | ||||
Tags | No tags attached. | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2023-09-07 19:22 | elong | New Issue | |
2023-09-07 19:22 | elong | Status | new => assigned |
2023-09-07 19:22 | elong | Assigned To | => elong |
2023-09-07 19:24 | elong | Status | assigned => resolved |
2023-09-07 19:24 | elong | Resolution | open => fixed |
2023-09-07 19:24 | elong | Fixed in Version | => 3.14.10 |
2023-10-27 20:06 | admin | Status | resolved => closed |