View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0006019 | SymmetricDS Pro | Bug | public | 2023-10-12 15:09 | 2024-05-28 12:20 |
Reporter | elong | Assigned To | elong | ||
Priority | normal | ||||
Status | closed | Resolution | fixed | ||
Product Version | 3.14.0 | ||||
Target Version | 3.14.10 | Fixed in Version | 3.14.10 | ||
Summary | 0006019: Oracle log miner stuck on resetting SCN number ORA-01281 | ||||
Description | Oracle log miner can get stuck on ORA-01281 message about an invalid SCN number if the range uses an ending SCN number that is not yet recorded. It currently handles the case where the starting SCN is before the first possible SCN. It doesn't handle the case where the ending SCN is after the last possible SCN. It gets stuck in a loop because it asks for the current SCN based on the current time, which isn't recorded yet. WARN Resetting SCN number from 1234 | ||||
Tags | dialect: oracle, log miner | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2023-10-12 15:09 | elong | New Issue | |
2023-10-12 15:09 | elong | Status | new => assigned |
2023-10-12 15:09 | elong | Assigned To | => elong |
2023-10-12 15:09 | elong | Tag Attached: log miner | |
2023-10-12 15:10 | elong | Tag Attached: dialect: oracle | |
2023-10-12 15:12 | elong | Status | assigned => resolved |
2023-10-12 15:12 | elong | Resolution | open => fixed |
2023-10-12 15:12 | elong | Fixed in Version | => 3.14.10 |
2023-10-12 15:17 | elong | Issue cloned: 0006020 | |
2023-10-12 15:17 | elong | Relationship added | related to 0006020 |
2023-10-27 20:06 | admin | Status | resolved => closed |
2024-05-28 12:20 | elong | Issue cloned: 0006450 | |
2024-05-28 12:20 | elong | Relationship added | related to 0006450 |