View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0006238 | SymmetricDS Pro | Bug | public | 2024-02-12 13:58 | 2024-02-13 14:22 |
Reporter | cquamme | Assigned To | cquamme | ||
Priority | normal | ||||
Status | closed | Resolution | fixed | ||
Product Version | 3.15.0 | ||||
Target Version | 3.15.4 | Fixed in Version | 3.15.4 | ||
Summary | 0006238: When the Process Builder returns non-zero for the Bulk Loader Screen, an UnknownFormatException can occur | ||||
Description | When then the Process Builder returns a non-zero in the Bulk Loader Screen, if the return value exceeds the size of an integer an "UnknownFormatException" will occur and it throws an error that is not very obvious or helpful. For ConnectDatabaseWizard_BulkLoader_Test_Failure_Process, we should use a "%d" rather than a "%i" For example, if the pb returns "-1,000,000,000", it should show that error, but instead it shows "UnknownFormatConversionException: Conversion = 'i'" | ||||
Tags | No tags attached. | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2024-02-12 13:58 | cquamme | New Issue | |
2024-02-12 13:58 | cquamme | Status | new => assigned |
2024-02-12 13:58 | cquamme | Assigned To | => cquamme |
2024-02-13 14:22 | cquamme | Status | assigned => resolved |
2024-02-13 14:22 | cquamme | Resolution | open => fixed |
2024-02-13 14:22 | cquamme | Fixed in Version | => 3.15.4 |
2024-03-19 16:20 | admin | Status | resolved => closed |