Summary0006390: Bi-directional log-based intermittent unrouted batches that should have routed
DescriptionWhen using bi-directional log-based replication, some batches will intermittently not be routed (status of unrouted) even though they should have been routed to other nodes. Incoming changes leave the source node ID variable set on connections which can then be used by other jobs to record changes with that source node ID, causing the changes to not route to that node. This appears to affect SQL-Server log-based (which supports bi-directional) and time-based log mining.
Tagsdialect: sql-server, log miner

Relationships

related to 0006389 closedelong Bi-directional log-based intermittent unrouted batches that should have routed 

Activities

There are no notes attached to this issue.

Issue History

Date Modified Username Field Change
2024-05-03 21:02 elong New Issue
2024-05-03 21:02 elong Status new => assigned
2024-05-03 21:02 elong Assigned To => elong
2024-05-03 21:02 elong Tag Attached: dialect: sql-server
2024-05-03 21:02 elong Tag Attached: log miner
2024-05-03 21:02 elong Issue generated from: 0006389
2024-05-03 21:02 elong Relationship added related to 0006389
2024-05-03 21:04 elong Status assigned => resolved
2024-05-03 21:04 elong Resolution open => fixed
2024-05-03 21:04 elong Fixed in Version => 3.15.7