View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0006428 | SymmetricDS Pro | Bug | public | 2024-05-16 17:44 | 2024-05-16 17:48 |
Reporter | elong | Assigned To | elong | ||
Priority | normal | ||||
Status | closed | Resolution | fixed | ||
Product Version | 3.15.0 | ||||
Target Version | 3.15.7 | Fixed in Version | 3.15.7 | ||
Summary | 0006428: Compare request may not complete when non-initiating node is the target | ||||
Description | When the non-initiating node is the target, it may not start the comparison even after the initiating node requests it. The initiating node starts the comparison by querying and extracting the table, but the status is never set to NE (new). The HTTP request to start comparison is received at the non-initiating node, but the status of RQ in the database prevents it from working on it. | ||||
Steps To Reproduce | 1. Use 2-tier server and client profile 2. Start a comparison request with the client as the source | ||||
Tags | compare repair | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2024-05-16 17:44 | elong | New Issue | |
2024-05-16 17:44 | elong | Status | new => assigned |
2024-05-16 17:44 | elong | Assigned To | => elong |
2024-05-16 17:44 | elong | Tag Attached: compare repair | |
2024-05-16 17:48 | elong | Status | assigned => resolved |
2024-05-16 17:48 | elong | Resolution | open => fixed |
2024-05-16 17:48 | elong | Fixed in Version | => 3.15.7 |
2024-06-07 16:46 | admin | Status | resolved => closed |