View Issue Details

IDProjectCategoryView StatusLast Update
0006556SymmetricDS ProBugpublic2024-08-13 15:33
Reporteremiller Assigned Toemiller  
Prioritynormal 
Status closedResolutionfixed 
Product Version3.15.0 
Target Version3.15.8Fixed in Version3.15.8 
Summary0006556: CPU monitor is inaccurate for systems with a Mac or Linux OS and more than 1 core
DescriptionThe CPU monitor is inaccurate for systems with a Mac or Linux operating system and more than 1 core. The top command can return a CPU usage of 100% multiplied by the number of cores, but the CPU monitor does not take this into account and just assumes a maximum CPU usage of 100%. Instead, it should divide the result by the number of cores.
Tagsmonitoring

Relationships

related to 0006555 closedemiller SymmetricDS CPU monitor is inaccurate for systems with a Mac or Linux OS and more than 1 core 

Activities

There are no notes attached to this issue.

Issue History

Date Modified Username Field Change
2024-08-13 15:21 emiller New Issue
2024-08-13 15:21 emiller Status new => assigned
2024-08-13 15:21 emiller Assigned To => emiller
2024-08-13 15:21 emiller Tag Attached: monitoring
2024-08-13 15:21 emiller Relationship added related to 0006555
2024-08-13 15:33 emiller Status assigned => resolved
2024-08-13 15:33 emiller Resolution open => fixed
2024-08-13 15:33 emiller Fixed in Version => 3.15.8
2024-08-16 17:45 admin Status resolved => closed