View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0004376 | SymmetricDS | Bug | public | 2020-04-28 20:52 | 2020-06-04 17:55 |
Reporter | rwfuller | Assigned To | elong | ||
Priority | normal | ||||
Status | closed | Resolution | fixed | ||
Product Version | 3.11.7 | ||||
Target Version | 3.11.9 | Fixed in Version | 3.11.9 | ||
Summary | 0004376: Monitor 'offlineNodes' does not capture offline nodes in detail | ||||
Description | The offlineNodes monitor does not save the offline nodes in SYM_MONITOR.DETAILS due to class MonitorTypeOfflineNodes's method serializeDetails does not capture result serializing list of offline nodes. | ||||
Tags | No tags attached. | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2020-04-28 20:52 | rwfuller | New Issue | |
2020-05-12 19:32 | rwfuller | Note Added: 0001716 | |
2020-05-20 17:17 | elong | Assigned To | => elong |
2020-05-20 17:17 | elong | Status | new => resolved |
2020-05-20 17:17 | elong | Resolution | open => fixed |
2020-05-20 17:17 | elong | Fixed in Version | => 3.11.9 |
2020-05-20 17:17 | elong | Target Version | => 3.11.9 |
2020-05-26 16:37 | elong | Status | resolved => closed |
2020-06-04 17:55 | admin | Changeset attached | => SymmetricDS 3.11 44539ea8 |