View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0004730 | SymmetricDS | Bug | public | 2020-12-29 17:37 | 2021-01-11 13:47 |
Reporter | josh-a-hicks | Assigned To | josh-a-hicks | ||
Priority | normal | ||||
Status | closed | Resolution | fixed | ||
Product Version | 3.12.0 | ||||
Target Version | 3.12.6 | Fixed in Version | 3.12.6 | ||
Summary | 0004730: MSSQL Bulk Writer continues to call start and end for the table even during fallback to default | ||||
Description | Need to return out of the start(table) and end(table) methods if the bulk loader has failed and is falling back to default loading. | ||||
Tags | No tags attached. | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2020-12-29 17:37 | josh-a-hicks | New Issue | |
2020-12-29 17:37 | josh-a-hicks | Status | new => assigned |
2020-12-29 17:37 | josh-a-hicks | Assigned To | => josh-a-hicks |
2020-12-29 17:39 | josh-a-hicks | Status | assigned => resolved |
2020-12-29 17:39 | josh-a-hicks | Resolution | open => fixed |
2020-12-29 17:39 | josh-a-hicks | Fixed in Version | => 3.12.6 |
2020-12-29 18:00 | josh-a-hicks | Changeset attached | => SymmetricDS 3.12 016fb885 |
2021-01-11 13:47 | admin | Status | resolved => closed |