View Issue Details
| ID | Project | Category | View Status | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 0005047 | SymmetricDS | Bug | public | 2021-07-01 19:50 | 2021-07-13 17:53 |
| Reporter | elong | Assigned To | elong | ||
| Priority | normal | ||||
| Status | closed | Resolution | fixed | ||
| Product Version | 3.12.0 | ||||
| Target Version | 3.12.10 | Fixed in Version | 3.12.10 | ||
| Summary | 0005047: Windows install to directory with parenthesis | ||||
| Description | Windows installation to a directory path that has parenthesis results in problems running the command line utilities. For example, installing to the common "C:\Program Files (x86)" directory for 32-bit applications. C:\Program Files (x86)\SymmetricPro\bin>sym_service.bat status \SymmetricPro') was unexpected at this time. The setenv.bat was changed to run a "cd" command to get the current directory (0002404), and then changed again to instead "echo %CD%" (0002532), but could more easily just set SYM_HOME to %CD% directly to avoid the parsing error. | ||||
| Tags | install | ||||
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2021-07-01 19:50 | elong | New Issue | |
| 2021-07-01 19:50 | elong | Status | new => assigned |
| 2021-07-01 19:50 | elong | Assigned To | => elong |
| 2021-07-01 19:50 | elong | Tag Attached: install | |
| 2021-07-01 19:53 | elong | Status | assigned => resolved |
| 2021-07-01 19:53 | elong | Resolution | open => fixed |
| 2021-07-01 19:53 | elong | Fixed in Version | => 3.12.10 |
| 2021-07-01 20:00 | admin | Changeset attached | => SymmetricDS 3.12 c3d1bd76 |
| 2021-07-13 17:53 | admin | Status | resolved => closed |