View Issue Details

IDProjectCategoryView StatusLast Update
0005207SymmetricDSBugpublic2022-04-11 19:27
Reporterpmarzullo Assigned Topmarzullo  
Prioritynormal 
Status closedResolutionfixed 
Product Version3.12.9 
Target Version3.12.16Fixed in Version3.12.16 
Summary0005207: Multi-tenant SymmetricDS instance fails to allow User Interface to function when some engines fail to start
DescriptionMulti-tenant SymmetricDS instance (more than one engine file exists in engines directory) fails to allow User Interface to display when half or more of the nodes fail to start the engine.
Steps To Reproduce1. Set up 4 nodes.
2. On 2 of the nodes, change the password to be incorrect.
3. Start up the instance.
4. UI will just show "Starting SymmetricDS"
Tagsui

Activities

pmarzullo

2022-01-26 17:40

developer   ~0002054

Patch has been created

Related Changesets

SymmetricDS: 3.12 6d2302d1

2022-01-26 17:38:38

pmarzullo

Details Diff
0005207: Multi-tenant SymmetricDS instance fails to allow User Interface
to function when some engines fail to start
Affected Issues
0005207
mod - symmetric-assemble/gradle.properties Diff File
mod - symmetric-server/src/main/java/org/jumpmind/symmetric/web/SymmetricEngineHolder.java Diff File

Issue History

Date Modified Username Field Change
2022-01-26 17:35 pmarzullo New Issue
2022-01-26 17:35 pmarzullo Status new => assigned
2022-01-26 17:35 pmarzullo Assigned To => pmarzullo
2022-01-26 17:35 pmarzullo Tag Attached: ui
2022-01-26 17:38 pmarzullo Summary Multi-tenant SymmetricDS instance fails to allow User Interface to function when all engines fail to start => Multi-tenant SymmetricDS instance fails to allow User Interface to function when some engines fail to start
2022-01-26 17:40 pmarzullo Status assigned => resolved
2022-01-26 17:40 pmarzullo Resolution open => fixed
2022-01-26 17:40 pmarzullo Note Added: 0002054
2022-01-26 18:00 pmarzullo Changeset attached => SymmetricDS 3.12 6d2302d1
2022-04-11 19:27 admin Status resolved => closed