View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0006278 | SymmetricDS | Improvement | public | 2024-03-07 17:18 | 2024-04-19 15:46 |
Reporter | pmarzullo | Assigned To | pmarzullo | ||
Priority | normal | ||||
Status | closed | Resolution | fixed | ||
Product Version | 3.15.3 | ||||
Target Version | 3.15.4 | Fixed in Version | 3.15.4 | ||
Summary | 0006278: Change file sync processing to make immediate request when batches are received or sent | ||||
Description | When a file synchronization is executed, whether it is a push or a pull of files, the initiator of the file sync should make an immediate request again if files are received when pulling or when files are sent when pushing. This will speed up the file synch process. | ||||
Tags | file sync | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2024-03-07 17:18 | pmarzullo | New Issue | |
2024-03-07 17:18 | pmarzullo | Status | new => assigned |
2024-03-07 17:18 | pmarzullo | Assigned To | => pmarzullo |
2024-03-07 17:18 | pmarzullo | Tag Attached: file sync | |
2024-03-07 17:27 | pmarzullo | Status | assigned => resolved |
2024-03-07 17:27 | pmarzullo | Resolution | open => fixed |
2024-03-07 17:27 | pmarzullo | Fixed in Version | => 3.15.4 |
2024-03-07 17:27 | pmarzullo | Note Added: 0002419 | |
2024-03-19 16:20 | admin | Status | resolved => closed |
2024-04-19 15:46 | pmarzullo | Changeset attached | => SymmetricDS 3.15 20a5cef6 |