Summary0006696: Max Batch Size insight shouldn't check reload channels
DescriptionCurrently, the Max Batch Size insight checks the max batch size for all channels. By default, the threshold is 10,001. In 3.16, the default max batch size for the reload channel will be increased beyond 10,000, which will trigger this insight on a fresh installation of SymmetricDS Pro. To prevent this behavior, the insight should not check the max batch size of reload channels.
Tagsconfiguration, monitoring

Activities

There are no notes attached to this issue.

Related Changesets

SymmetricDS: 3.16 32a4095f

2025-01-10 13:04:52

evan-miller-jumpmind

Details Diff
0006696: Updated documentation for Max Batch Size insight Affected Issues
0006696
mod - symmetric-assemble/src/asciidoc/configuration/monitors.ad Diff File

Issue History

Date Modified Username Field Change
2025-01-09 21:32 emiller New Issue
2025-01-09 21:32 emiller Status new => assigned
2025-01-09 21:32 emiller Assigned To => emiller
2025-01-09 21:32 emiller Tag Attached: configuration
2025-01-09 21:32 emiller Tag Attached: monitoring
2025-01-10 13:05 emiller Status assigned => resolved
2025-01-10 13:05 emiller Resolution open => fixed
2025-01-10 13:05 emiller Fixed in Version => 3.16.0
2025-01-10 14:00 Changeset attached => SymmetricDS 3.16 32a4095f