Summary | 0006696: Max Batch Size insight shouldn't check reload channels | ||||
Description | Currently, the Max Batch Size insight checks the max batch size for all channels. By default, the threshold is 10,001. In 3.16, the default max batch size for the reload channel will be increased beyond 10,000, which will trigger this insight on a fresh installation of SymmetricDS Pro. To prevent this behavior, the insight should not check the max batch size of reload channels. | ||||
Tags | configuration, monitoring | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2025-01-09 21:32 | emiller | New Issue | |
2025-01-09 21:32 | emiller | Status | new => assigned |
2025-01-09 21:32 | emiller | Assigned To | => emiller |
2025-01-09 21:32 | emiller | Tag Attached: configuration | |
2025-01-09 21:32 | emiller | Tag Attached: monitoring | |
2025-01-10 13:05 | emiller | Status | assigned => resolved |
2025-01-10 13:05 | emiller | Resolution | open => fixed |
2025-01-10 13:05 | emiller | Fixed in Version | => 3.16.0 |
2025-01-10 14:00 | Changeset attached | => SymmetricDS 3.16 32a4095f |