Summary | 0003076: MySQL binary collation sequence causes incorrect decoding of text data from source | ||||
Description | If the source database platform is different than the target platform AND the target platform is MySQL and the target MySql database has fields of type TEXT (tinytext, longtext, mediumtext, text) AND the target database or table has a binary collation sequence, the target data load will incorrectly assume it was passed binary data for the field. This results in the target load attempting to decode text data incorrectly, resulting in errors such as follows: Incorrect string value... for column... | ||||
Tags | No tags attached. | ||||
related to | 0001261 | resolved | reload-table doesn't work with tables that have collate latin1_bin |
Date Modified | Username | Field | Change |
---|---|---|---|
2017-04-26 17:45 | gwilmer | New Issue | |
2017-04-26 17:45 | gwilmer | Status | new => assigned |
2017-04-26 17:45 | gwilmer | Assigned To | => gwilmer |
2017-04-26 17:46 | gwilmer | Resolution | open => fixed |
2017-04-26 17:46 | gwilmer | Fixed in Version | => 3.8.22 |
2017-04-26 18:00 | gwilmer | Changeset attached | => SymmetricDS 3.8 36f3b7c5 |
2017-04-26 18:00 | gwilmer | Status | assigned => resolved |
2017-05-01 18:03 | chenson | Status | resolved => closed |
2019-05-31 16:06 | elong | Relationship added | related to 0001261 |